950 resultados para LED-BASED PHOTOMETER


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this manuscript, an automatic setup for screening of microcystins in surface waters by employing photometric detection is described. Microcystins are toxins delivered by cyanobacteria within an aquatic environment, which have been considered strongly poisonous for humans. For that reason, the World Health Organization (WHO) has proposed a provisional guideline value for drinking water of 1 mu g L-1. In this work, we developed an automated equipment setup, which allows the screening of water for concentration of microcystins below 0.1 mu g V. The photometric method was based on the enzyme-linked immunosorbent assay (ELISA) and the analytical signal was monitored at 458 nm using a homemade LED-based photometer. The proposed system was employed for the detection of microcystins in rivers and lakes waters. Accuracy was assessed by processing samples using a reference method and applying the paired t-test between results. No significant difference at the 95% confidence level was observed. Other useful features including a linear response ranging from 0.05 up to 2.00 mu g L-1 (R-2 =0.999) and a detection limit of 0.03 mu g L-1 microcystins were achieved. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multilevel PAM is investigated for a LED-based SI-POF link. Using PAM-8, transmission at a record 3 Gbit/s is demonstrated for a maximum length of 25 m step index POF with offline post-receiver processing. © 2013 OSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multilevel PAM is investigated for a LED-based SI-POF link. Using PAM-8, transmission at a record 3 Gbit/s is demonstrated for a maximum length of 25 m step index POF with offline post-receiver processing. © 2013 OSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The light calibration system is one of the key components of Neutron Wall detector. It is used to calibrate the electronics and to monitor the long-term stability of the detector modules. With the detaile investigations, a calibration system with high-power LED (3W) driven by the fast pulses has been carried out. It is also tested together with the detector module of the Neutron Wall and the result of the preliminary calibration demonstrates that it fulfills the needs. It's a new design proposal to the light calibration system of the fast scintillator detector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design and development of a cost-effective, simple, sensitive and portable LED based fiber optic evanescent wave sensor for simultaneously detecting trace amounts of chromium and nitrite in water are presented. In order to obtain the desired performance, the middle portions of two multimode plastic clad silica fibers are unclad and are used as the sensing elements in the two arms of the sensor. Each of the sensor arms is sourced by separate super bright green LEDs, which are modulated in a time-sharing manner and a single photo detector is employed for detecting these light signals. The performance and characteristics of this system clearly establish the usefulness of the technique for detecting very low concentrations of the dissolved contaminants.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Droplets formed at the tip of a tube under the same conditions possess extreme uniformity of form, volume and weight. These properties of liquid drop formation have been known for a long time and consequently many applications for the drop have been found in instrumentation and chemical analysis methods. In the present paper, we report on the analytical use of a dynamic LED-based flow-through optical absorption detector with optical path length controlled by continuous dropping of a solution. This arrangement consists of a flow cell built within a high-intensity red LED (lambda (max)=630 nm). The feasibility of the detector is demonstrated by colorimetric determination of methylene blue, and ammonium by Berthelot's reaction, in a flow-injection system. For ammonium, the reaction forms a blue dye (indophenol) with a maximum absorption at 630-650 nm. The detection limit, considered as 3 times the signal of the blank, is better than 125 mu g l(-1). The small flow cell represents a good combination of optical path length, low volume and fast washout. This detector can be used advantageously in automated methods and can represent a solution to problems of optical detection involving gas bubbles and precipitation of particles in turbidimetric applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to test a newly developed LED-based fluorescence device for approximal caries detection in vitro. We assembled 120 extracted molars without frank cavitations or fillings pairwise in order to create contact areas. The teeth were independently assessed by two examiners using visual caries detection (International Caries Detection and Assessment System, ICDAS), bitewing radiography (BW), laser fluorescence (LFpen), and LED fluorescence (Midwest Caries I.D., MW). The measurements were repeated at least 1 week later. The diagnostic performance was calculated with Bayesian analyses. Post-test probabilities were calculated in order to judge the diagnostic performance of combined methods. Reliability analyses were performed using kappa statistics for nominal data and intraclass correlation (ICC) for absolute data. Histology served as the gold standard. Sensitivities/specificities at the enamel threshold were 0.33/0.84 for ICDAS, 0.23/0.86 for BW, 0.47/0.78 for LFpen, and 0.32/0.87 for MW. Sensitivities/specificities at the dentine threshold were 0.04/0.89 for ICDAS, 0.27/0.94 for BW, 0.39/0.84 for LFpen, and 0.07/0.96 for MW. Reliability data were fair to moderate for MW and good for BW and LFpen. The combination of ICDAS and radiography yielded the best diagnostic performance (post-test probability of 0.73 at the dentine threshold). The newly developed LED device is not able to be recommended for approximal caries detection. There might be too much signal loss during signal transduction from the occlusal aspect to the proximal lesion site and the reverse.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study describes a novel spectral LED-based tunable light source used for customized lighting solutions, especially for the reconstruction of CIE (Commission Internationale de l’Éclairage) standard illuminants. The light source comprises 31 spectral bands ranging from 400 to 700 nm, an integrating cube and a control board with a 16-bit resolution. A minimization algorithm to calculate the weighting values for each channel was applied to reproduce illuminants with precision. The differences in spectral fitting and colorimetric parameters showed that the reconstructed spectra were comparable to the standard, especially for the D65, D50, A and E illuminants. Accurate results were also obtained for illuminants with narrow peaks such as fluorescents (F2 and F11) and a high-pressure sodium lamp (HP1). In conclusion, the developed spectral LED-based light source and the minimization algorithm are able to reproduce any CIE standard illuminants with a high spectral and colorimetric accuracy able to advance available custom lighting systems useful in the industry and other fields such as museum lighting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Water treatment using photocatalysis has gained extensive attention in recent years. Photocatalysis is promising technology from green chemistry point of view. The most widely studied and used photocatalyst for decomposition of pollutants in water under ultraviolet irradiation is TiO2 because it is not toxic, relatively cheap and highly active in various reactions. Within this thesis unmodified and modified TiO2 materials (powders and thin films) were prepared. Physico-chemical properties of photocatalytic materials were characterized with UV-visible spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectrometry (XPS), inductively coupled plasma optical emission spectroscopy (ICP-OES), ellipsometry, time-of-flight secondary ion mass spectrometry (ToF-SIMS), Raman spectroscopy, goniometry, diffuse reflectance measurements, thermogravimetric analysis (TGA) and nitrogen adsorption/desorption. Photocatalytic activity of prepared samples in aqueous environment was tested using model compounds such as phenol, formic acid and metazachlor. Also purification of real pulp and paper wastewater effluent was studied. Concentration of chosen pollutants was measured with high pressure liquid chromatography (HPLC). Mineralization and oxidation of organic contaminants were monitored with total organic carbon (TOC) and chemical oxygen demand (COD) analysis. Titanium dioxide powders prepared via sol-gel method and doped with dysprosium and praseodymium were photocatalytically active for decomposition of metazachlor. The highest degradation rate of metazachlor was observed when Pr-TiO2 treated at 450ºC (8h) was used. The photocatalytic LED-based treatment of wastewater effluent from plywood mill using commercially available TiO2 was demonstrated to be promising post-treatment method (72% of COD and 60% of TOC was decreased after 60 min of irradiation). The TiO2 coatings prepared by atomic layer deposition technique on aluminium foam were photocatalytically active for degradation of formic and phenol, however suppression of activity was observed. Photocatalytic activity of TiO2/SiO2 films doped with gold bipyramid-like nanoparticles was about two times higher than reference, which was not the case when gold nanospheres were used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sounds of the Suburb was a commissioned public art proposal based upon a brief set by Queensland Rail for the major redevelopment at their Brunswick Street Railway Station, Fortitude Valley, Brisbane. I proposed a large scale, electronic artwork to be distributed across the glass fronted structure of their station’s new concourse building. It was designed as a network of LED based ‘tracking’ - along which would travel electronically animated, ‘trains’ of text synchronised to the actual train timetables. Each message packet moved endlessly through a complex spatial network of ‘tracks’ and ‘stations’ set both inside, outside and via the concourse. The design was underpinned by large scale image of sound waves etched onto the architecture’s glass and was accompanied by two inset monitors each presenting ghosted images of passenger movements within the concourse, time-delay recorded and then cross-combined in realtime to form new composites.----- Each moving, reprogrammable phrase was conceived as a ‘train of thought’ and ostensibly contained an idea or concept about popular cultures surrounding contemporary music – thereby meeting the brief that the work should speak to the diverse musical cultures central to Fortitude Valley’s image as an entertainment hub. These cultural ‘memes’, gathered from both passengers and the music press were situated alongside quotes from philosophies of networking, speed and digital ecologies. These texts would continually propagate, replicate and cross fertlise as they moved throughout the ‘network’, thereby writing a constantly evolving ‘textual soundcape’ of that place. This idea was further cemented through the pace, scale and rhythm of passenger movements continually recorded and re-presented on the smaller screens.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This publication is the culmination of a 2 year Australian Learning and Teaching Council's Project Priority Programs Research Grant which investigates key issues and challenges in developing flexible guidelines lines for best practice in Australian Doctoral and Masters by Research Examination, encompassing the two modes of investigation, written and multi-modal (practice-led/based) theses, their distinctiveness and their potential interplay. The aims of the project were to address issues of assessment legitimacy raised by the entry of practice-orientated dance studies into Australian higher degrees; examine literal embodiment and presence, as opposed to cultural studies about states of embodiment; foreground the validity of questions around subjectivity and corporeal intelligence/s and the reliability of artistic/aesthetic communications, and finally to celebrate ‘performance mastery’(Melrose 2003) as a rigorous and legitimate mode of higher research. The project began with questions which centred around: the functions of higher degree dance research; concepts of 'master-ness’ and ‘doctorateness’; the kinds of languages, structures and processes which may guide candidates, supervisors, examiners and research personnel; the purpose of evaluation/examination; addressing positive and negative attributes of examination. Finally the study examined ways in which academic/professional, writing/dancing, tradition/creation and diversity/consistency relationships might be fostered to embrace change. Over two years, the authors undertook a qualitative national study encompassing a triangulation of semi-structured face to face interviews and industry forums to gather views from the profession, together with an analysis of existing guidelines, and recent literature in the field. The most significant primary data emerged from 74 qualitative interviews with supervisors, examiners, research deans and administrators, and candidates in dance and more broadly across the creative arts. Qualitative data gathered from the two primary sources, was coded and analysed using the NVivo software program. Further perspectives were drawn from international consultant and dance researcher Susan Melrose, as well as publications in the field, and initial feedback from a draft document circulated at the World Dance Alliance Global Summit in July 2008 in Brisbane. Refinement of data occurred in a continual sifting process until the final publication was produced. This process resulted in a set of guidelines in the form of a complex dynamic system for both product and process oriented outcomes of multi-modal theses, along with short position papers on issues which arose from the research such as contested definitions, embodiment and ephemerality, ‘liveness’ in performance research higher degrees, dissolving theory/practice binaries, the relationship between academe and industry, documenting practices and a re-consideration of the viva voce.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

LED-based carrierless amplitude and phase modulation is investigated for a multi-gigabit plastic optical fibre link. An FPGA-based 1.5 Gbit/s error free transmission over 50 m standard SI-POF using CAP64 is achieved, providing 2.9 dB power margin without forward error correction. © 2012 OSA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

LED-based carrierless amplitude and phase modulation is investigated for a multi-gigabit plastic optical fibre link. An FPGA-based 1.5 Gbit/s error free transmission over 50 m standard SI-POF using CAP64 is achieved, providing 2.9 dB power margin without forward error correction. © 2012 Optical Society of America.